Hydrophobic coating stabilizes lead-free perovskite ammonia sensor against humidity

Researchers at the Indian Institute of Technology Gandhinagar and the Institut de Chimie Moléculaire de l'Université de Bourgogne (ICMUB) in Dijon, France, have shown that coating a lead-free halide perovskite ammonia sensor with a thin hydrophobic polymer layer substantially improves its reliability under humid conditions, addressing one of the main obstacles keeping perovskite-based gas sensors as lab curiosities rather than practical devices.

Halide perovskites are attractive for room-temperature chemiresistor gas sensors thanks to their high surface activity and easily tunable electronic structure, but their strong sensitivity to atmospheric moisture has been a persistent problem: adsorbed water perturbs the perovskite lattice, generates defects, and promotes ion migration, causing sensor readings to drift, show hysteresis between rising and falling gas concentrations, and lose reproducibility under realistic, humidity-varying conditions. Prior stabilization approaches, including compositional tuning and inorganic passivation layers, have generally either left residual humidity sensitivity in place or blocked gas access to the sensing material enough to hurt performance.

 

The team worked with vacancy-ordered Cs2SnI6, a lead-free, tin-based halide perovskite, synthesized hydrothermally and deposited as a thin film on interdigitated indium tin oxide electrodes to form the ammonia-sensing chemiresistor. Onto this film, they deposited a thin overlayer of polystyrene (PS), a hydrophobic polymer, and used X-ray diffraction, X-ray photoelectron spectroscopy, and Raman spectroscopy to confirm that the Cs2SnI6 film's crystal phase and vibrational structure were preserved after the polymer coating. The coating's effect on surface chemistry was substantial: the water contact angle rose from about 45° on the pristine film to about 140° after PS deposition, indicating a sharp increase in surface hydrophobicity.

Tested for ammonia detection under 20-60% relative humidity, the uncoated Cs2SnI6 device showed pronounced humidity- and concentration-history-dependent behavior, with its response shifting depending on prior exposure conditions. The PS-coated device, by contrast, showed substantially reduced hysteresis in its normalized ammonia response across the same humidity range. Rather than eliminating humidity sensitivity in the device's absolute baseline current, which still evolved over time, the coating instead stabilized the normalized response signal that indicates gas concentration. The PS-coated sensor also detected ammonia down to lower concentrations than the uncoated version, with a limit of detection of about 1.4 ppm compared with about 2.7 ppm for the pristine film, and maintained its response over 30 days of measurements and 50 rapid exposure-and-recovery cycles.

This simple, hydrophobic polymer overlayer can meaningfully improve the practical reproducibility of lead-free perovskite gas sensors under real-world humidity conditions without resorting to more complex compositional or structural modifications, describing the approach as a step toward moving perovskite-based ammonia sensing beyond proof-of-concept demonstrations and closer to viable room-temperature environmental monitoring devices.

Posted: Sep 11,2026 by Roni Peleg